Hardware Functions
In-Out
Performances
The best to suit your needs!
Housing (H x W x D)
Display type
Variables on display
Instantaneous variables
Energy variables
Accuracy
Temperature drift
Sampling rate
System type
Voltage inputs (Un)
Current inputs (In)
Digital inputs
Primary of CT/VT
Measurements:
Variables
Harmonic distortion
Outputs: Pulse
Alarm
Analogue
Serial
Digital filter
Other characteristics
Power supply
Approvals
Protection degree
WM23 96 is a modular power quality analyzer that allows
the operator to continuously monitor the mains. All meas-
urements with a direct connection up to 830VAC (phase-
phase), up to 20kV (VT connection) and up to 5.000A (CT
connection) allow the operator to use WM23-96 in all the
light and medium industry applications. This flexible instru-
ment has a standard IP65 protection degree, a 0.5 accuracy
class, an FFT analysis up to the 16th harmonics and, on
request, up to 2 alarms, one analogue output and one
RS422/485 or RS232 communication port.
WM23 96 can be equipped with different modules like the
three digital input one. Two of those inputs can be connected
to the official Watt-hour meter to synchronise the W and VA
demand calculation, while the last input can be used to lock
the programming of the equipment.
This power quality analyzer is able to show any single current
and voltage total harmonic distortion on which it is possible
to connect an alarm output. The wide LCD display with high
contrast feature is able to show all the measurements and in
addition the recording of the MAX active powers: W
L1, WL2,
W
L3, (on request A
L1
, A
L2
, A
L3
max value) W
sys, Wdmd and the
MIN power factors: PF1, PF2, PF3, PF
sys.
Comm
Power Quality Analyzer WM23 96
96x96x140mm
LCD (back lighted)
YES
4x3 1/2 DGT
N.A.
V
LN-A: ±(0.5% F.S.+2DGT)
V
LL-W-VA: ±(1% F.S. +2DGT)
var: ±(2% F.S. +2DGT)
THD: ±(3% F.S. +2DGT)
200ppm/°C
1.5 samples/s
Bal.: 3-phase, Unbal.:3-phase
57/100VAC, 120/208VAC
230/400VAC, 380/660VAC
5A
2 for W
dmd and VAdmd syncronization
1 for program lock
Prog.: CT up to 5000A, VT up to 20kV
TRMS method
Sys:V
LN,VLL,An,VA,W,Wdmd,VAdmd, var,
PF, Hz.
Single-phase:VLN,VLL,A, W, var,PF,THD.
THD up to 16th H (V and A)
N.A.
Up to 2 (relay or open collector)
1 (5mA, 10mA, 20mA, 1V,5V, 10V DC)
RS485 (Modbus), RS232
Action: on variables and outputs
Modular concept, plug-in modules.
Phase asymmetry control
24, 48, 115,230VAC
18 to 60V AC/DC, 90 to 260VAC/DC
CE, cURus, cCSAus
IP65
WM23 96