CARLO GAVAZZI WM3-96 - PROGRAMMING Especificações

Consulte online ou descarregue Especificações para Processadores CARLO GAVAZZI WM3-96 - PROGRAMMING. CARLO GAVAZZI WM3-96 - PROGRAMMING Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 2 - Innovation Always

The Energy Management components for . . .Transportation: AirportsBig and Heavy Industry: Steel, Shipyards, Mines,Wood, Car PlantsIn the big and heav

Página 3

Telecom: TelecommunicationsWater: Drinkable Water Plants, Water Distribution PlantsA water treatment anddistribution system is veryhard to manage, b

Página 4 - What are and

12DC Energy MeteringAC Energy MeteringGas and Water MeteringMulti Function MeteringVariables AnalysisPower Quality AnalysisCT connectionsDirect high-c

Página 5 - Why different buses

13EM26 96WM12 96WM12 DINWM14 96WM14 DINWM22 DINWM3 96PQT 90WM5 96PQT HWM4 96WM10 DINCPT DINCVT DIN** WM5-96 only

Página 6 - Installationbus

14EM24 DINEM11 DINPower analyzer features into an ultracompact energy meterNew solution providing a fullparameters control, saving alsospace in the sm

Página 7 - The main Bus devices

EM24 DIN, EM3 DIN, EM4 DIN, WM22 DIN65A and 100A availableConnections for cableswith cross-section areafrom 6 to 35mm2insteadof passing-by typesassur

Página 8 - Stadiums

A new concept of ModularityIn addition to the obvious need to improve theperformances of the measuring instruments in order tokeep them up-to-date wit

Página 9 - Load Control

Technical Advantagesand Cost Benefits• PLUG and PLAY modules common to all models; maximum in-field flexibility.• Possibility to expand the number and

Página 10 - Wood, Car Plants

18TypesDescriptionHousingPort 1ConnectionsPIN assignementPort 2RS485 working modeLine BiasLine terminationConnectionsBaud rateProtectionIndication(by

Página 11 - Pump Level Flow Alarms

19Housing (H x W x D)Display type Var. on displayInstantaneous variablesEnergy variablesAccuracyTemp. drift Refresh rateSystem typeVoltage inputs

Página 12

Carlo Gavazzi Creations:Distinctive FeaturesAs with all objects created by mankind, they can beidentified by qualities inspired by man, such as anunmi

Página 13 - * WM5-96 only

20HardwareFunctionsIn-OutPerformancesThe best to suit your needs!Modular Energy Meter EM3 DIN90x162.5x63mm (9-DIN modules)MechanicalYESN.A.6+1 DGTClas

Página 14 - AR1060 Module

21Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Modular Utility Meter EM4 DIN90x162.5x63 (9-DIN modules)LCD (back lighted), h: 8.5mm

Página 15

22Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Energy Meter EM21 72D72x72x65mm (4-DIN modules)2 lines LCD, h: 7mmYES3x3 DGTs6+1 DGT

Página 16 - A new concept of Modularity

23Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Energy Meter EM23 DIN71x90x65mm (4-DIN modules)LCD, h: 9mmYES2 lines 1x7 DGTs; 3x3 D

Página 17 - Technical Advantages

24Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Energy Analyzer EM24 DIN90x71x65mm (4-DIN modules)LCD (STN technology), h: 7mmYES3x

Página 18

2596x96x61.4mmLCD (2-colour with back light STN technology), h: 9.5mmYES3x4 DGTs8 DGTsW-VA-PF: ±(1% RDG+2DGT) var: ±(2% RDG+2DGT) VLN-A: ±(0.5% RDG+1D

Página 19 - EM10 DIN EM11 DIN

26Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Multifunction meter WM10 DIN71x90x65mm (4-DIN modules)LCD, h: 9mmYES2 lines, 3x3 DG

Página 20 - The best to suit your needs!

27Hardware FunctionsIn-OutPerformancesThe best to suit your needs!Multifunction Meters WM12 DIN WM12 9690x107.5x64.5mm (6-DIN mod.) (WM12 DIN)96x96x

Página 21

2890x107.5x64.5mm (WM14 DIN) (6-DIN mod.)96x96x61.5mm (WM14 96)LED, h: 14mmYES3 DGTs8+1 DGTs5+2 DGTsW-VA:±(1% F.S.+1DGT)var:±(2% F.S. +1DGT)VLL: ±(1.5

Página 22 - EM21 72D

29Hardware FunctionsIn-OutPerformancesThe best to suit your needs!90x162.5x63mm (9-DIN modules)LCD (back lighted), h: 8.5mmYES4x3 1/2 DGTs71/2 DGTsVLN

Página 23 - EM23 DIN

WM3-96 introduces the modularphilosophy in the panel mountinganalysers.EM4-DIN implements the modularconcept in the DIN-rail analysers andenergy meter

Página 24

Hardware FunctionsIn-OutPerformancesThe best to suit your needs!96x96x124mmGraphic, back lighted LCDYESSel: 4x3 1/2 DGTs or 4x4 DGTs4x9 DGTs (total),

Página 25

Main variablesVariables that can be monitored and displayedSystemAverage(dmd)Min RS485 Analogue outVLL,VLNV asymmetryAAnHzVAvarWPF+kWh (*)-kWh (*)+kva

Página 26 - WM10 DIN

Hardware FunctionsIn-OutPerformancesThe best to suit your needs!96x96x124mm (WM4); 90x90x140 (PQT)Graphic, LCD back lighted (WM4 only)YES (WM4); NO (P

Página 27 - WM12 96 WM12 DIN

(*) Total and time-period energies, daily and night gas.Powerful variable analysis and great communication capabilities: this is the strength of WM4 9

Página 28 - WM14 96 WM14 DIN

Hardware FunctionsIn-OutPerformancesThe best to suit your needs!96x96x129 (WM5); 90x90x140 (PQT H)Graphic, back lighted LCD (WM5 only)WM5 96: YES; PQT

Página 29 - WM22 DIN

Main variablesVariables that can be monitored and displayedSystemAverage(dmd)MinRS485/232 OpticalAnalogue OutVLL,VLNV asymmetryAAnHzVAvarWPF+kWh (*)-k

Página 30

36Ethernet/Internet communication module with WEB server capability. Compatible with WM4-96 and PQT-90All the instantaneous single phase and system

Página 31 - Main variables

37Compact Power Transducer CPT DINBasic and Advanced functionsCPT DIN is a compact transducer available as a Basicversion for measurement and data ret

Página 32 - WM4 96 PQT 90

38Hardware FunctionsIn-OutPerformancesThe best to suit your needs!4-Channel Ammeter WM14 A20490x107.5x64.5mm (6-DIN modules)LED, h: 14mmYES2x 3 DGTsN.

Página 33

DC Energy Analyzer VMU-E, VMU-XThis energy analyzer is a modular combination of twomodules VMU-E and VNU-X for DC V, A, W and kWhmetering.VMU-E is pro

Página 34 - WM5 96 PQT H

Green levies, tighter operating margins and profits area few economic drivers forcing operators to use moreintelligent power management strategies. Re

Página 35

TrendsA selectable set of variables (different from instrument to instrument) can be stored inthe PowerSoft database with a selectable time interval s

Página 36 - AR1060 WEB server

Alarms and eventsAn active alarms window (that automatically pops up in any case of alarm) advises theuser if a setpoint has been exceeded or if a com

Página 37

CptBSoft and CptASoft have been developed to program theparameters and read in real-time mode the variables of thecompact power transducer (Basic and

Página 38 - WM14 A204 and ROG400

SMS setting Up to 8 different SMS can be sent from the instrument to up to 5 phone numbers incase of alarm activation or deactivation.Real-time variab

Página 39 - VMU-E and VMU-X

44TypesCurrent TransformersTADK TADK2 CTD-1X CTD-2X CTD-3XTypes CTD-4X CTD-8V CTD-8H CTD-9V CTD-9H CTD-10V CTD-10H TACO 2000.5max ∅ 23 mm65x44x44 mmEN

Página 40 - PowerSoft Energy Manager

45TypesSplit Core Current TransformersCTD-6S CTD-8STypesCTD-9S CTD-10S ROG400CTD-5SClassBus-bar sizeDimensions (H x W x D)StandardsAccuracy class depe

Página 41

46TypesEM10/EM11 DIN EM21 72DVMU-E/VMU-X90 x 18 x 67Modular DC energy analyzerV, A, W, kWh0 to 400VDC0 to 20ADC (0 to 120mV/0 to 1000A with external s

Página 42 - Specific instrument Software

EM3 DIN EM4 DINEM26 9696 x 96 x 61.53-phase energy analyzerSystem: VLL,VLN, An, var, VA, WWdmd,VAdmd, VA, Hz, %THD-V,%THD-A, kWh, kvarh,hour counter.M

Página 43

TypesWM14 DIN/96 Basic & AdvancedWM22WM12 DIN/9690 x 107,8 x 64,5 (DIN)96 x 96 x 61.5 (96)3-phase multifunction meterSystem:VLL, An, W, var,VA, Wd

Página 44 - CTD and TAD series

PQT 90 CPT DIN Basic & AdvancedWM5 96/PQT H96 x 96 x 124 (WM5); 90 x 90 x 140 (PQT H)MODULARSmart power quality analyzer (WM5) / transducer (PQT

Página 45 - CTD-9S CTD-10S ROG400

Why different buses and solutions• RS422-RS485 communication in a localnetwork:all the measurements made by singleinstruments can be gathered through

Página 46 - LL,VLN,A

50(*) Only for alarm purposeList of modules: Modular Panel MountingDescriptionWM3-96 base WM4-96 basePQT-90 base WM5-96 base with optical portWM5-96 b

Página 47 - Energy Meters

100AAccuracy of the main variablesStandard-compliant energy meteringHousing front protection degreeMax measured current in case ofdirect connectionDis

Página 48 - Basic & Advanced

8028157 BRO EM ENG 06-2009CARLO GAVAZZIAutomation ComponentsOUR SALES NETWORK IN EUROPEOUR SALES NETWORK IN NORTH AMERICAOUR SALES NETWORK IN ASIA AND

Página 49

When an idea becomes a great idea …The introduction of the Climate Change Levy (CCL) isaffecting consumers of energy in one way or another.The basic o

Página 50

Energy ManagementThe other Fieldbus compatible instruments:DIN-rail mounting: EM10, EM11,EM3, EM4, EM21, EM23, EM24, WM14, WM22,CPT, PQTPanel mounting

Página 51

The Energy Management components for . . .Commercial Buildings: Shopping Malls, Resorts, Supermarkets, RestaurantsServices and Infrastructures: School

Página 52 - CARLO GAVAZZI

Production Facilities: Cost AllocationLight and Medium Industry: Load ControlSince the cost pressure onproduction is becoming higherand higher, the

Comentários a estes Manuais

Sem comentários