84
Digital Panel Meters
Dimensions
(mm) H x W x D
Description
Input Specifications
Range code
Accuracy
Indication Max.
Min.
Range selection/decimal
Sampling rate
Functions
Output Specifications
General Specifications
Power supply
Safety Standards
Approvals/Marks
Option
Ordering References
AC/DC AC/DC Temperat./Resist.
Rate
Ammeter Voltmeter Measurement Meter
Types MDI 40 A MDI 40 V MDI 40 CF MDI 40 TF
48 x 96 x 83
Microprocessor-based
meter/controller.
Temperature
and
resistance measurem.
(C° or F°).
3 3/4-digit display.
Pt100, Ni100, 200,
TC: J, L, K, T, E [CFX];
Pt1000, 2000,
TC: J, L, K, T, E [CFP]
Pt100/1000 ±0.15%FS
Tc (5°C to the limit)
±0.15%FS
Depending on range
and type of the temp.
probe
2 times/s
Password protection
Scaling factor
Diagnostics
Programm.
Digital filter
Measurement selection
Analogue from 0 to 20
mA from 0 to 10V [A].
Serial RS485
unidirectional [R].
Serial RS485
bidirectional [S]
[W]=[A]+R], [Y]=[A]+[S]
120[E], 230[D], 240[F],
24[A], 48[B], 115[C]
VAC, 9 to 32[3] VDC,
40 to 150 [6] VDC
EN 61010-1,
IEC 61010-1, VDE0411
CE - CSA
Interactive setpoints
[01], trop. + IP65 [XT]
See pag. 101
48 x 96 x 124
Microprocessor-based
meter/controller.
AC/DC Ammeter.
3 3/4-digit display.
Two alarm setpoints
2 mA, 20 mA, 2 A, 5 A
(40 to 400 Hz) [AOB]
200 mA [A4X];
TRMS 2 mA, 20 mA, 2 A,
5 A (40-1000 Hz) [AOT]
AC/DC: ±0.1% full scale
AC TRMS:
±0.2% full scale
DC: max. 3999
min. -1999
AC & AC TRMS:
max. 3999, min. 0
Programmable
4 times/s
Password protection
Scaling factor
Diagnostics
Programm.
Digital filter
Max./Min. data hold
AC/DC selection
Analogue from 0 to 20
mA from 0 to 10V [A].
Serial RS485
unidirectional [R].
Serial RS485
bidirectional [S]
[W]=[A]+R], [Y]=[A]+[S]
120[E], 230[D], 240[F],
24[A], 48[B], 115[C]
VAC, 9 to 32[3] VDC,
40 to 150 [6] VDC
EN 61010-1,
IEC 61010-1, VDE0411
CE - UL - CSA
Interactive setpoints
[01], trop. + IP65 [XT]
See pag. 101
48 x 96 x 83
Microprocessor-based
meter/controller. Rate
speed, frequency and
period measurement .
4 -digit display.
0.001 to 500 Hz [TF1]
0.1 to 50 MHz [TF2]
Sygnal type: DC signal
(PNP, NPN, NAMUR,
TTL free of voltage
contacts. Voltage up
to 30 VDC; AC signals
pick-up voltages up to
500 VAC
9999,
0 (AC) -1999 (DC)
Programmable
Password protection
Scaling factor
Diagnostics
Programm.
Digital filter
Range selection
Analogue from 0 to 20
mA from 0 to 10V [A].
Serial RS485
unidirectional [R].
Serial RS485
bidirectional [S]
[W]=[A]+R], [Y]=[A]+[S]
120[E], 230[D], 240[F],
24[A], 48[B], 115[C]
VAC, 9 to 32[3] VDC,
40 to 150 [6] VDC
EN 61010-1,
IEC 61010-1, VDE0411
CE - CSA
Tropicalization +
IP65 [XT]
See pag. 101
48 x 96 x 83
Microprocessor-based
meter/controller.
AC/DC Voltmeter.
3 3/4-digit display.
Two alarm setpoints
200 mV, 2 V, 20 V, 200 V,
500 V, (40 to 400 Hz)
[VOB] TRMS 200 mV,
2 V, 20 V; 200 V, 500 V,
(40 to 1000 Hz) [VOT]
AC/DC: ±0.1% full scale
AC TRMS:
±0.2% full scale
DC: max. 3999
min. -1999
AC & AC TRMS:
max. 3999, min. 0
Programmable
4 times/s
Password protection
Scaling factor
Diagnostics
Programm.
Digital filter
Max./Min. data hold
AC/DC selection
Analogue from 0 to 20
mA from 0 to 10V [A].
Serial RS485
unidirectional [R].
Serial RS485
bidirectional [S]
[W]=[A]+R], [Y]=[A]+[S]
120[E], 230[D], 240[F],
24[A], 48[B], 115[C]
VAC, 9 to 32[3] VDC,
40 to 150 [6] VDC
EN 61010-1,
IEC 61010-1, VDE0411
CE - UL - CSA
Interactive setpoints
[01], trop. + IP65 [XT]
See pag. 101
Vista de página 88