4 Specifications ar
e subject to change without notice EM2172D DS ENG 280708
EM21 72D
Self power supply 18 to 260V
AC (48-62Hz).
Across input “VL1” and “N”
Power consumption ≤2VA/1W
Power supply specifications
Surge On current and voltage
m
easuring inputs circuit:
6
kV;
R
adio frequency suppression According to CISPR 22
Standard compliance
Safety IEC60664, IEC61010-1
EN60664, EN61010-1
EN62052-11
M
etrology EN62053-21, EN62053-23,
E
N50470-3
P
ulse output DIN43864, IEC62053-31
Approvals CE
Connections Screw-type
Cable cross-section area 2.4 x 3.5 mm
Min./Max. screws tighten-
ing torque: 0.4 Nm / 0.8 Nm
Housing
Dimensions (WxHxD) 72 x 72 x 65 mm
Material Noryl PA66,
self-extinguishing: UL 94 V-0
Mounting Panel and DIN-rail
Protection degree
Front IP50
Screw terminals IP20
Weight Approx. 400 g (packing
included)
Operating temperature -25°C to +55°C (-13°F to
131°F) (R.H. from 0 to 90%
non-condensing @ 40°C)
according to EN62053-21
and EN62053-23.
Storage temperature -30°C to +70°C (-22°F to
158°F) (R.H. < 90% non-
condensing @ 40°C)
according to EN62053-21
and EN62053-23.
I
nstallation category
C
at. III (IEC60664,
EN60664).
Insulation (for 1 minute) 4000 VRMS between mea-
suring inputs and digital
output.
Dielectric strength 4000 VRMS for 1 minute.
Noise r
ejection
CMRR
100 dB, 48 to 62 Hz.
EMC According to EN62052-11
Electrostatic discharges 15kV air discharge;
Immunity to irradiated Test with current: 10V/m
from 80 to 2000MHz;
Electromagnetic fields Test without any current:
30V/m from 80 to
2000MHz;
Burst On current and voltage
measuring inputs circuit: 4kV
Immunity to conducted
disturbances 10V/m from 150KHz to
80MHz
General specifications
Insulation between inputs and outputs
Measuring Inputs
Opto-Mosfet output Communication port Self power supply
Measuring Inputs
- 4kV 4kV 0kV
Opto-Mosfet output
4kV - - 4kV
Communication port
4kV - - 4kV
Self power supply
0kV 4kV 4kV -
NOTE: all the models have, mandatorily
, to be connected to exter
nal current transformers.